ETIM class: |
Power cable < 1 kV, for permanent installation
|
Conductor material: |
Copper |
Conductor surface: |
Bare |
Nominal cross section conductor: |
2,5 mm² |
Conductor category: |
Class 1 = solid |
Number of cores: |
2 |
Twisted cores: |
no |
Material core insulation: |
Polyvinyl chloride (PVC) |
Specification core insulation: |
Other |
Core identification according to HD 308 S2: |
yes |
Identification/coding colour core: |
Other |
Core identification: |
Colour |
Core colour: |
Several |
With protective conductor: |
no |
Max. conductor temperature: |
70 °C |
Screen: |
no |
Drain wire: |
no |
Protective barrier: |
None |
Armouring/reinforcement: |
None |
Material outer sheath: |
Polyvinyl chloride (PVC) |
Specification material outer sheath: |
Other |
Colour outer sheath: |
White |
Cable geometry: |
Flat |
Reaction-to-fire according to EN 13501-6: Class: |
Eca |
Reaction-to-fire according to EN 13501-6: Smoke production: |
None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: |
None |
Reaction-to-fire according to EN 13501-6: Acidity: |
None |
Halogen free according to EN 60754-1/2: |
no |
Flame retardant: |
According to IEC/EN 60332-1-2 |
Low smoke (according to EN 61034-2): |
no |
Low temperature resistant according to EN 60811-504+505+506: |
no |
Oil resistant according to EN IEC 60811-404: |
no |
Insulation integrity: |
None |
Min. permitted bending radius, stationary application/permanent installation: |
4 mm |
Permitted cable outer temperature during assembling/handling: |
-5 - 70 °C |
Permitted cable outer temperature after assembling without vibration: |
-40 - 70 °C |
Nominal voltage U0: |
300 V |
Nominal voltage U: |
500 V |
Circuit integrity: |
None |
Shape of conductor: |
Round |
Suitable as installation cable: |
yes |
Certified for shipboard application: |
no |
Suitable as medium-voltage cable: |
no |
Suitable as high-voltage cable: |
no |
Certified as airport lighting cable: |
no |
Weight: |
81 |
Circuit integrity according to EN 50200: |
No |
Circuit integrity according to EN 50200 annex E: |
no |
Circuit integrity according to IEC 60331-3: |
No |
Circuit integrity according to IEC 60331-21: |
no |
Flame retardant according to EN 60332-1-2: |
yes |
Flame retardant according to EN 60332-3-21 (Cat A F/R): |
no |
Flame retardant according to EN 60332-3-22 (Cat A): |
no |
Flame retardant according to EN 60332-3-23 (Cat B): |
no |
Flame retardant according to EN 60332-3-24 (Cat C): |
no |
Flame retardant according to EN 60332-3-25 (Cat D): |
no |
Halogen free according to EN 60754-1: |
no |
Halogen free according to EN 60754-2: |
no |
Halogen free according to EN 60754-3: |
no |